Pressure tank for a deep well: diaphragm tank, pressure switch and pressure

A pressure tank set for a deep well is in practice an assembly: a submersible pump in the borehole, a non-return valve, a diaphragm pressure tank, a pressure switch and a pressure gauge in the building. The tank holds water under pressure, and the pressure switch starts the pump when the pressure drops and stops it once the pressure has built up again. For this to work without the pump constantly “clicking” on and off, you need to match the tank capacity to the pump yield and set the air pressure in the tank slightly below the cut-in threshold.
The trench, the PE pipe from the well to the house and the general rules for the connection are covered in the article on connecting a deep well to a house. Here we deal only with the pressure set itself.
Pressure tank set for a deep well: what it consists of
The word “hydrophore” brings to mind a surface pump standing in the cellar. Such a pump draws water only from a shallow water table, in practice down to about 7-8 m. With a drilled well the water usually lies deeper, so the pump is lowered into the borehole and only the “pressure” part of the set stays in the house.
| Component | What it does | Where it is |
|---|---|---|
| Submersible pump | Pumps water from the borehole into the installation | In the well casing, below the water level |
| Non-return valve | Stops water flowing back into the well after the pump switches off | In the pump or just above it, often a second one at the set |
| Diaphragm pressure tank | Stores a reserve of water under pressure and limits the number of pump starts | In the building, in a frost-free room |
| Pressure switch | Switches the pump on and off according to the set pressure thresholds | On the fitting by the tank |
| Pressure gauge | Shows the pressure in the installation | On the same fitting |
| Shut-off, drain and safety valves | Let you isolate the set, drain the water and protect against overpressure | Before and after the tank |
The pump is selected according to the depth, the water level and the yield of the borehole. We describe this stage in the guide submersible pump for a deep well. The tank and the pressure switch are selected only once the specific pump is known.
How a diaphragm pressure tank works
A diaphragm tank has a rubber diaphragm inside. On one side is water, on the other a cushion of air (sometimes nitrogen) at a set pre-charge pressure. When the pump delivers water, the diaphragm compresses the air. When you open a tap, the compressed air pushes water into the installation and the pump stays off.
The pump starts only when the pressure drops to the cut-in threshold set on the pressure switch. As a result, washing your hands or filling a glass of water does not start the motor in the well.
An important point when buying: the capacity on the plate is not the amount of water the tank delivers between pump starts. With typical household settings the usable volume is roughly 25-35% of the nominal capacity. A 100 l tank therefore delivers about 30 l of water between the pump switching off and switching on again.
Which diaphragm pressure tank to choose for a well
The tank capacity is chosen according to the pump yield, not the number of taps. Submersible motor manufacturers recommend that the motor runs for at least about 1 minute after each start. During that time it dissipates the heat generated at start-up. A simple rule follows from this: the water the pump delivers in one minute should fit within the usable volume of the tank.
Example for a pressure switch setting of 2.0 bar (cut-in) and 3.5 bar (cut-out) and a pre-charge pressure of 1.8 bar. With these values the tank delivers about 31% of its nominal capacity.
| Pump yield at the operating point | Water delivered in 1 minute | Approximate nominal tank capacity |
|---|---|---|
| 1.2 m³/h | 20 l | approx. 65 l, in practice 80 l |
| 1.8 m³/h | 30 l | approx. 100 l |
| 2.4 m³/h | 40 l | approx. 130 l, in practice 150 l |
| 3.0 m³/h | 50 l | approx. 160 l, in practice 200 l |
The table is calculated from the Boyle-Mariotte law for one set of settings. With a smaller pressure difference (for example 2.0-3.0 bar) the tank delivers less water, about 23% of its capacity, so it must be larger. For the calculations use the pump yield at the pressure at which it actually operates, not the maximum from the catalogue. The former is usually clearly lower. You can make a preliminary estimate of the pump’s operating point in the pump parameter calculator.
A smaller tank is enough with variable frequency drive (VFD) control, as we explain below. With a well with a weak inflow the pump cannot deliver more than the borehole yields, which we describe in the article on water inflow into a well.
Connecting a pressure tank set to a well: diagram and steps
Below are the components in the order of water flow, from the bottom of the well to the installation in the house. The details depend on the pump and tank model, so always compare them with the manufacturer’s instructions.

- A submersible pump hung in the well casing, below the lowest water level during pumping, with a safety rope.
- A non-return valve at the pump outlet (many pumps have one built in). One motor manufacturer recommends fitting the valve no further than about 7.5 m above the pump and below the pumping water level if the pump does not have its own.
- A delivery pipe in the borehole and the wellhead, then PE pipe in the ground to the building. The laying depth and the passage through the wall are covered in the article on the well and pump connection.
- A shut-off valve at the entry to the building.
- A five-way fitting (a so-called five-way manifold) by the tank. The pressure switch, pressure gauge, tank connection and outlet to the installation are mounted on it.
- A diaphragm tank, as close to the pressure switch as possible, so that the pressure switch measures the same pressure as the tank.
- A safety valve and a drain valve at the set.
- A shut-off valve after the set, then any filters and a water treatment system, and then the domestic installation.
The pressure switch controls the power supply to the pump. Single-phase pumps often also have a box with a capacitor and motor protection. The electrical part, including a separate circuit with a residual current device (RCD), is done by a qualified electrician.
What pressure to set on a pressure tank set
Two values get mixed up here, and it is worth keeping them apart:
- operating pressure, that is, the pump cut-in and cut-out thresholds set on the pressure switch,
- air pre-charge pressure in the empty tank, measured at the small valve on the side or top of the tank.
In single-family homes the cut-in threshold is usually set in the range 1.5-2.5 bar, and the difference between cut-in and cut-out at about 1-1.5 bar. For example, a popular pressure switch is factory-set to 1.4-2.8 bar. The upper threshold must be one that the pump reaches with a margin at the given water level depth. If the pump barely reaches the cut-out threshold, it runs without end.
With typical household pumps with a yield of 1-3 m³/h, the arrangement that most often works is: cut-in 2.0 bar, cut-out 3.5 bar and a pre-charge pressure in the tank of 1.8 bar. The tank is usually 100 l for pumps up to about 2 m³/h and 150-200 l for higher-capacity pumps.
The pre-charge pressure in the tank is set slightly below the cut-in threshold. Manufacturers’ instructions give this in different ways, but the result is similar: 0.9 × the cut-in pressure, or about 0.15-0.2 bar less than the cut-in threshold.
| Pump cut-in (pressure switch) | Pre-charge pressure in the empty tank |
|---|---|
| 1.5 bar | approx. 1.3-1.35 bar |
| 2.0 bar | approx. 1.8 bar |
| 2.5 bar | approx. 2.25-2.3 bar |
| 3.0 bar | approx. 2.7-2.8 bar |

The pre-charge pressure is measured only with the tank empty on the water side: switch off the pump, close the inlet valve, and open a tap or the drain valve until the pressure gauge shows zero. Only then put the gauge on the air valve and pump up or release air. A measurement with water in the tank will show the water pressure, not that of the air cushion.
Tanks come with a factory pre-charge pressure, often 1.5-2 bar. Do not assume that it suits your pressure switch. Check it before the first start-up and then at least once a year. Some manufacturers recommend checking every six months.
Adjusting the pressure switch step by step
In popular mechanical pressure switches there are two springs with nuts under the cover. The larger one sets the cut-in threshold and shifts the whole operating range. The smaller one sets the differential, that is, how much higher than the cut-in the pump switches off. In some models the screws indicate the cut-out threshold and the differential, so first check the markings in the instructions.
- Read the current settings. Open a tap and watch the pressure gauge: note the pressure at which the pump starts and the pressure at which it stops.
- Switch off the power to the pump and the pressure switch. Under the cover there are live terminals at 230 V or 400 V.
- Remove the cover and set the cut-in threshold with the larger nut. Tightening usually raises the threshold, loosening lowers it. Turn it by half a turn, no more.
- Set the differential with the smaller nut. Pressure switches have their own differential range, for example 0.6-2.3 bar, and you cannot go outside it.
- Replace the cover, switch the power on and watch several full cycles on the pressure gauge.
- If you have changed the cut-in threshold, empty the tank and correct the pre-charge pressure according to the table above.
The last step is often skipped. Raising the cut-in threshold without correcting the air in the tank reduces the amount of water delivered between starts, and the pump starts switching on more often.
Symptoms of wrong settings and what to check
The most common complaint is a pump that switches on every dozen or so seconds, or every time a tap is opened. Pump manufacturers usually list four causes here: wrong pressure switch settings, wrong pre-charge pressure in the tank, a leaking non-return valve and a ruptured diaphragm.
| Symptom | Most common cause | What to check |
|---|---|---|
| The pump switches on every few seconds | No air in the tank or a ruptured diaphragm | The pre-charge pressure with the tank empty; whether water comes out of the air valve |
| The pump starts by itself although nobody is drawing water | A leaking non-return valve or a leak in the installation | Whether the pressure on the pressure gauge drops with the taps closed |
| The pump does not switch off | A cut-out threshold higher than the pump can reach, a drop in the water level, a worn pump | The maximum pressure the pump reaches; the water level in the well |
| Large pressure swings at the taps | Differential on the pressure switch too large | The differential setting |
| Little water between starts | Pre-charge pressure too high or too low, tank too small | Pre-charge pressure and capacity relative to the pump yield |
| Knocking and banging in the pipes after the pump switches off | Non-return valve | The condition and type of the non-return valve |
Every start heats the motor and stresses the pressure switch contacts. Submersible motor manufacturers give limits on starts per day, for example 100 for single-phase 4-inch 0.75-4 kW motors in one of the manuals. With a tank without an air cushion such a limit is easily exceeded.
Pressure tank set or variable frequency drive
A set with a pressure switch gives a pressure that swings between two thresholds. If that bothers you in the shower, or you have large, variable demand, consider constant-pressure control. We compare the options in the article on the variable frequency drive (VFD) for a submersible pump.
How much does it cost to install a pressure tank set at a well
The cost of the equipment depends on the pump, the tank capacity and the accessories, so we do not give a single amount. In the ARCHE price list, pump installation costs PLN 700 net plus materials. A full deep well connection installation is PLN 1,500 net plus materials, and the composition of the set is agreed with the client after measurements of the well. We also service and adjust existing pressure tank sets, including those installed by other companies. You will find current rates in the deep well price list.
Frequently asked questions
What pressure should there be in a pressure tank?
The air pressure in the empty tank is set slightly below the pump cut-in threshold, usually 0.9 × the cut-in pressure or about 0.2 bar less. With cut-in at 2.0 bar this will be about 1.8 bar. Always measure it with the pump switched off and the water drained.
Which diaphragm tank for a submersible pump?
One whose usable volume will hold at least a minute of pump operation. With typical settings the tank delivers about 25-35% of its capacity, so a pump with a yield of 1.8 m³/h needs a tank of about 100 l. Larger pumps need 150-200 l or another method of control.
Why does the pump in the well keep switching on and off?
Most often the tank has no air or the diaphragm is ruptured. The second typical cause is a leaking non-return valve, which lets water flow back into the well. Check the pre-charge pressure with the tank empty and watch the pressure gauge with the taps closed.
How do I set the pressure switch for a pressure tank set?
With the power off, set the cut-in threshold with the larger nut and the difference between cut-in and cut-out with the smaller one. Then match the pre-charge pressure in the tank to the new cut-in threshold. Make changes in small steps and check them on the pressure gauge.
Can a submersible pump work without a diaphragm tank?
Not with a pressure switch alone, because the pump would switch on every time a tap was opened. Even systems with a variable frequency drive and constant pressure need a small tank that covers small draw-offs and leaks.
Sources
- Grundfos, Hydro Solo-S, installation and operating instructions: pre-charge pressure 0.9 × cut-in pressure, check at least once a year, causes of starts that are too frequent
- Zilmet, well tank manual (rev. 08.2020): pre-charge pressure 2 psi below cut-in, check every 6 months, tank close to the pressure switch, safety valve
- Franklin Electric, AIM Manual: Submersible Systems (2026): minimum run time 1 minute, limits on starts per day, position of the non-return valve
- Italtecnica PM5 / PT5 / PT12 pressure switch instructions: factory settings, differential range, order of adjustment
Want to connect your well to the house, or sort out a set where the pump keeps switching on? ARCHE from Trzebinia selects the pump and accessories based on the measurements of your specific well, carries out the installation together with the electrical connection, and services existing sets in Lesser Poland (Małopolska) and Silesia. Call +48 784 038 407 or +48 692 353 826 or write via the contact form. We call back within 24 hours.