Connecting a deep well to a house: diagram and order of work

Connecting a deep well to a house is one chain of equipment: a pump hung in the well, a rising main in the ground, a valve where the pipe enters the building, a pressure tank with its controls and the domestic installation. Water always flows from the pump to the tap in that order, and the filter is chosen only after the water test. Below we describe each element of the diagram, the installation stages and the first start-up.
Legal position as at 16.11.2026. The route and the trench between the well and the house are covered in a separate article on the well-to-house connection.
Diagram of the installation from well to tap
The installation has 13 elements, from the pump at the bottom of the well to the distribution of water in the house. Some sit by the well, some in the ground and the rest in the building. The table shows them in the order in which the water flows.
| No. | Element | Where it is | What it is for |
|---|---|---|---|
| 1 | Submersible pump | in the well, below the water table | pushes the water up |
| 2 | Stainless steel support cable | in the well | holds the pump and lets you pull it out |
| 3 | Rising main | in the well, from the pump to the wellhead | carries the water out of the pump |
| 4 | Power cable in a corrugated conduit | next to the rising main | powers the pump, the conduit protects it mechanically |
| 5 | Stainless steel wellhead | on top of the well pipe | closes the opening and leads the pipe and cable out |
| 6 | Protective enclosure or well chamber | above the wellhead | protects it from rainwater and frost |
| 7 | Pipe in the ground (PE32) | from the well to the building | carries the water to the house |
| 8 | Passage through the foundation | in the wall or foundation | brings the pipe into the building, sealed with a wall sleeve |
| 9 | Shut-off valve | where the pipe enters the building | lets you cut off the water without pulling out the pump |
| 10 | Pre-filter or water treatment system | after the valve | cleans the water once matched to the test result |
| 11 | Pressure tank (hydrophore) | in a frost-free room | stabilises the pressure and limits how often the pump switches on |
| 12 | Controller or variable frequency drive (VFD) | next to the tank | switches the pump on and off, protects it from running dry |
| 13 | Domestic installation (PP or PEX) | in the building | distributes the water to the draw-off points |
The depth at which the pump is hung, its distance from sediment and the well screens, the way it is suspended and the cooling flow the motor needs are set according to the construction of the well and the pump manufacturer’s instructions. Also check the internal diameter of the well pipe, because the nominal diameter alone does not tell you whether the whole unit will fit. How to choose the pump itself for the well is covered in the article what pump for a deep well.
Pressure switch or VFD: which to use to control the pump
To control the pump you choose between a pressure switch and a VFD. A pressure switch turns the pump on when the pressure in the tank falls to a set value and turns it off once the pressure rises above it. A VFD changes the pump speed so as to hold a constant pressure in the installation.
| Feature | Pressure switch | VFD |
|---|---|---|
| Pump operation | switches on and off, at full power | smoothly changes speed to match current demand |
| Pressure at the tap | varies between the switch-on and switch-off value | constant, as set |
| Pressure tank | needed, larger | needed, can be smaller |
| Typical use | a simple house, low demand | a house with several draw-off points, where constant pressure matters |
ARCHE installs sets with a pressure switch and with a VFD. The operation, selection and settings of a VFD are covered in the article on a VFD for a submersible pump. Whichever you choose, the controls should protect the pump from dry running and overload. A pump running without water is ruined within minutes, and the protection costs many times less than a new pump.
Connecting a deep well to a house step by step
The order of work matters, because measurements from the well decide the pump, and the water test result decides the filter. The list below shows the typical order for a new installation.
- Before choosing equipment, measure the depth of the well, the water table level (static and dynamic), the yield from the pumping test and the distance from the well to the building. These data decide the pump and the length of the route.
- The pump is chosen for the required flow and head at the operating point, taking into account the dynamic level, the difference in height to the point of use, the required pressure and the losses in the pipework. The maximum head and the maximum flow do not occur at the same time, so check the curve of the specific model. The operating output should not exceed the safe abstraction rate set for the well.
- The pump is lowered on a stainless steel cable, the rising main and cable are connected, and the well is closed with the wellhead. A non-return valve is fitted after the pump to stop water running back when it switches off. Installation takes experience, because the pump can jam or break away during lowering, so it is usually commissioned from a company, as with the submersible pump installation at ARCHE.
- The pipe from the well to the house lies below the frost line on a bed of sand, with warning tape above the pipe and cable. For drinking water, use a pipe with a document confirming it is suitable for contact with water. The depth, the fall and the protection of shallow sections are chosen to suit the plot.
- The pipe enters the building through a bore with a wall sleeve, sealed watertight. Without sealing, moisture from the ground gets into the room.
- A shut-off valve is fitted at the entry, and in a frost-free room the pressure tank and the controller or VFD. The pump is powered from a separate circuit with a 30 mA residual current device (RCD), and the work is done by a qualified electrician.
- The filter and treatment are chosen after the water test, not before. We cover the scope in the article on a filter for well water.
- Welded PP or PEX pipes are connected to the domestic installation, and the whole is checked with a leak test according to the instructions of the pipe and fittings manufacturer. The tank’s pre-charge pressure is set according to the tank’s instructions.
- Run the first batch of water outside the building until it is clear, and only then switch on the domestic installation. Check that the pump does not switch on too often and that the pressure does not drop.
- Have the water tested in a laboratory after start-up, before you begin to drink it. The laboratory compares the result with the values in the Regulation of the Minister of Health of 22.05.2026 on the quality of water for consumption.
How to connect a pressure tank to a submersible pump
The pressure tank stands after the shut-off valve and the filter, and before the domestic installation. The pump pushes water through the pipe to the tank, the controls work there (a pressure switch or a VFD with a pressure sensor), and from there the water goes to the house. Thanks to the tank, the pump does not switch on every time a tap is opened.
The capacity of the tank and its pre-charge pressure depend on the pump output, the control settings and the number of people in the house. We cover the selection rules in the article on a pressure tank for a deep well. The tank with the pump and controls is placed where frost does not reach, with access for servicing.
Well water and mains water in one house
A well and the mains can supply one building, but the arrangement must not allow secondary contamination of the network. It is safest to run two separate installations. If the design provides for a shared arrangement, protection against backflow is chosen by a licensed designer in agreement with the water utility. A non-return valve alone is not permission to connect the two sources.
The most common mistakes when connecting a well
Most faults come down to a few recurring mistakes:
- a pipe laid too shallow or without protection at the sections by the well and the building, which risks freezing and bursting,
- no controls with dry-run protection, so the pump is ruined running without water,
- no residual current device on the pump circuit,
- a pump chosen “by eye”: one that is too weak gives low pressure upstairs, and one that is too powerful wears out quickly,
- a filter bought before the water test,
- a direct connection between the well and the mains.
Paperwork before installation
Building a water intake up to 30 m for ordinary use of water, and abstraction not exceeding 5 m³ per day on annual average for your own household or farm, are exempt from a water-law permit and notification (Article 33 and Article 395 of the Water Law Act (Prawo wodne)). These are separate conditions covering the construction of the intake and the abstraction of water. A deeper borehole, or use of the water beyond ordinary use, requires checking the correct procedure with Wody Polskie. The exemption does not remove location requirements, the protection of water intakes or the geological regulations. The details are covered in the article on a permit for a deep well.
How much installation costs and what it depends on
The cost of the installation depends on the depth of the well, the length of the route, the pump chosen, the controls and whether the water needs treatment. That is why this article does not give a single amount for every house. According to the ARCHE price list, pump installation costs PLN 700 net plus materials, and a complete connection installation PLN 1,500 net plus materials. When comparing offers, establish the full amount payable and the scope of materials. The data for a quote conversation (depth, distance, height to the highest tap) collected in the connection planner speed up the arrangements with the contractor.
Want someone to plan and carry out the whole installation, from the pump to the tank? Write to us or call: +48 784 038 407. We work in Lesser Poland (Małopolska) and Silesia, and we call back within 24 hours.
Frequently asked questions
How do you connect a deep well to a house?
The pump in the well is joined by the rising main to the pipe in the ground, which enters the building. From there the water passes through a shut-off valve, a filter and a pressure tank with its controls, and reaches the domestic installation. It all starts with measuring the well’s parameters, and ends with a leak test and a water test.
What does the diagram for connecting a deep well with a tank look like?
From the pump the water goes through the rising main to the wellhead, through the pipe in the ground to the building, and through a shut-off valve and a filter to the pressure tank. The tank works with the pump controls, that is a pressure switch or a VFD with a pressure sensor. After it comes the domestic installation.
Pressure switch or VFD for a submersible pump?
A pressure switch turns the pump on and off within a set pressure range, so the pressure at the tap varies slightly. A VFD holds a constant pressure by changing the pump speed. ARCHE installs both solutions, and the choice depends on the number of draw-off points and the convenience you expect.
Can I connect a deep well to a house myself?
Some of the work, such as the trench and laying the pipe, can be done yourself. Installing the pump in the well takes experience, and the pump’s power circuit with a residual current device should be made by a qualified electrician. Leave the choice of filtration until the water test result.
Does the water need testing after connecting the well?
We always recommend it. The State Sanitary Inspectorate (Sanepid) recommends testing well water before first use and at least once a year, and also after flooding or a failure. For drinking water, the parametric value for E. coli and enterococci is 0 in 100 ml (Regulation of the Minister of Health of 22.05.2026).
Can well water be combined with mains water in one house?
Both sources can supply one house, but the arrangement must not allow contamination of the water network. It is safest to separate the installations, and a shared arrangement requires a design and agreement with the water utility.