Low pressure and frequent pump starts
First compare how the installation behaves with all outlets closed and during use. Do not raise the control settings until you know where the problem comes from.
Low pressure in one place
If the problem affects only one tap or section, note which other points work correctly. Checking a local component usually requires a different sequence of steps than diagnosing the whole intake.
When the pressure is correct with no abstraction but drops during use, note the flow and the number of open outlets. A static reading alone does not describe what the installation can do.
Pressure drops even with the taps closed
Make sure that no watering, tank filling or automatic filter backwash is running. Record the change in pressure and the time until the pump restarts. The cause may be a loss of water or a leak in the fittings, but this needs to be checked.
Do not dismantle valves under pressure. Let the service centre establish in which part of the system the drop occurs.
The pump starts every few moments
In an installation with a tank and a pressure switch, the service centre should check, among other things, the settings, the condition of the diaphragm and the operating conditions of the tank. In a regulated (variable-speed) system, the sensor and the control settings also need checking.
The pre-charge pressure is checked according to the instructions for the specific tank and with the water side properly relieved. A reading taken in a random state of the installation can be misleading. Do not carry over values from another model.
A simple record of observations
- The pressure before opening a tap and during use.
- The number of outlets in use.
- The running time and the interval between starts.
- Alarms and the date the cartridges were last replaced.
- Changes made just before the symptom appeared.
Such a record helps tell a flow restriction, a control problem and a loss of water apart.