I have a problem with my well

Cleaning and rehabilitating a well

Cleaning should have an identified reason and a measurable aim. A fall in yield, sand and a decline in quality may call for different actions.

Gather the data from before the problem

Prepare the documentation of the intake, the acceptance pumping test, water results and the service history. Note when the change was noticed and whether it coincided with higher abstraction, a repair or a change of equipment.

Do not attribute every pressure drop to the well becoming clogged. The cause may also be the pump, a pipe, fittings, the controls or a filter in the building.

Define the scope of the diagnosis

Ask the service centre to state the measurements needed before choosing a method. Depending on the situation, it may be useful to compare the flow and the water level, inspect the well structure or carry out a camera inspection. A camera image does not replace a water quality test.

The method of work is chosen to suit the construction, condition and cause of the restriction. Not every well can be treated the same way, and deepening it or interfering with its structure needs a separate assessment.

What to put in the work order

  • The symptom and the aim of the work, for example restoring specified abstraction conditions.
  • The scope of dismantling, cleaning and any disinfection.
  • How the pump, the installation and any residues from the work will be handled.
  • The method of checking the result and the documents after completion.
  • Additional costs that need your approval before they are incurred.

Compare the result before and after

Check the result of the work with a measurement under the described conditions. If the aim was to improve water quality, a proper follow-up test is needed. A mere statement that cleaning was done is not confirmation that the water is drinkable.

Record the parameters achieved and the recommendations for further use. The service centre should not promise a lasting yield without taking the conditions of the intake into account.

Sources:

Checked 8 October 2026

Read and plan further

Next guidePump not working: fault, alarm or power loss