Construction and equipment

What pipe for a deep well: diameter, type and rising main

Mateusz Skotnicki , updated 11 min read

What pipe for a deep well: a well pipe, a pump and an aquifer in cross-section

What pipe for a deep well? A drilled well uses PVC-U well pipes: solid in the upper part and screen pipe at the level of the aquifer. We install PVC-U pipes with a diameter of 125 mm, and 110 mm with a thicker gravel pack in sandy ground. The diameter has to suit the pump, because the pump must fit inside the pipe and be cooled by the water flowing past it. The rising main from the pump to the house is a separate pipe, usually made of polyethylene.

What pipe for a deep well: three different pipes in one well

Three pipes with different jobs and different diameters work in one well. Mixing them up is the most common reason why descriptions found online seem to contradict each other.

  1. The temporary casing stabilises the hole during drilling. With our percussion method it is pulled out after the well pipes have been installed, so it does not stay in the ground.
  2. The well pipes form the permanent column of the well: solid pipes and a screen through which water enters from the aquifer. A filter gravel pack is placed around the column.
  3. The rising main runs from the pump upwards and on to the house. It is thin, because it carries water under pressure and is not part of the well structure.

When offers or forums mention a “casing pipe for a deep well”, check which pipe is meant: the temporary one used for drilling or the column that stays. The full arrangement of components is shown in the article on the deep well diagram, and you will find a short overview of the parts in the Help Centre: well components: pipes, screen, gravel pack and wellhead.

What well pipes are made of

Well pipes for drinking water are made of PVC-U. The manufacturer Gamrat describes its well pipes as made of PVC-U, approved for drinking water systems, compliant with the PN-G-02323 standard and offered in pressure classes PN 10, PN 12.5 and PN 16, in diameters DN 110 - DN 450, in a threaded version with an O-ring seal. When buying and accepting the work, it is therefore worth asking for a hygiene certificate for the pipes and seals.

The colour of a pipe is not proof of quality. What matters are the manufacturer’s markings, the pressure class and a document approving the material for contact with water intended for human consumption. Sewer and water supply pipes are no substitute for well pipes: the well column works under the pressure of the ground and the gravel pack, and a threaded well pipe has different joints from a sewer pipe.

What diameter of pipe for a deep well

The diameter of the well pipe is chosen to suit the pump, not the number of litres you expect. In its material on sizing a pump for a domestic well, the pump manufacturer Grundfos gives the rule that the nominal diameter of the pump should match the diameter of the hole, and that with a hole that is too large, the lack of water velocity at the motor can overheat it. If the water is above 30°C, the flow at the motor should be at least 0.15 m/s. Always check the requirements of a specific model in its manual.

The table below is a starting point for a conversation with the contractor, not a replacement for the pump datasheet.

Submersible pump What to check in the well pipe Notes
4 inch (about 102 mm nominal), e.g. the Lowara e-GS series inside diameter of the pipe, not the nominal one the most common choice for a house; in a 110 mm pipe the clearance is smaller than in a 125 mm one
6 inch (about 152 mm nominal), e.g. the Lowara Z6 series inside diameter of the pipe, dimensions of the pump unit with its cable higher yields; a pipe clearly wider than 125 mm
any dimensions from the model datasheet, with the cable and the non-return valve clearance for removal and servicing

For its wells, the manufacturer Gamrat recommends the 4-inch e-GS series (flow up to 21 m³/h) and the 6-inch Z6 series (up to 78 m³/h). With a 4-inch pump you need to check the inside diameter of a DN 110 or DN 125 pipe, because in a 110 mm pipe the clearance is smaller. In sandy ground we use 110 mm with a thicker gravel pack, and in other cases 125 mm. We cover the choice of the pump itself for depth and yield separately: which pump for a deep well.

Does a wider well give more water

No. A larger diameter does not create additional resources, because the quantity of water is determined by the aquifer, the length and construction of the screen and the gravel pack. A wider pipe holds a larger pump and increases the volume of water in the column, but it does not replace a good investigation and a pumping test. A diameter that is too large for the pump also worsens motor cooling, as Grundfos writes in the material from the previous section.

The screen manufacturer Gamrat gives a rule for choosing a screen: the velocity of water flowing from the aquifer into the screen should not exceed 3 cm/s, and the finer the gravel of the pack, the greater the resistance and the lower the yield. The screen and gravel pack are therefore chosen to suit the grain size of the aquifer, not the diameter of the pipe. We discuss well yield in the article on deep well yield. With fine, water-bearing sand, a poor screen design ends with sand being carried out, which we write about in the article running sand in a well.

Screen pipe and solid pipe: what goes where

The solid pipe runs from the wellhead to the aquifer, and the screen pipe stands exactly at the level of that aquifer. The manufacturer describes slotted and mesh screens in diameters DN 110 - DN 450, and mesh screens are used for loose layers of fine-grained sands and gravels. The length of the screen is chosen to suit the thickness of the aquifer and the drop in the water level. A screen that is too long is not an advantage either, because it shortens the trouble-free life of the intake, and one that is too short restricts the flow.

The pump should not stand on the bottom or in sediment. It hangs above the screen or at its level, with a reserve of submergence during pumping. The upper end of the column finishes with the wellhead, which we describe in the article on the deep well wellhead.

What rising main for a submersible pump: 32 or 40 mm

The rising main is a separate decision and depends on the flow, the length of the run and the pressure losses, not on the diameter of the well. Polyethylene PE100 pipes are used for well systems. Gamrat states that its PE pipes for a well system are offered in diameters DN 25 - DN 63, in classes PN10 and PN16.

Three things decide the choice between 32 and 40 mm:

  • the flow of the pump: the greater it is, the higher the water velocity in a thin pipe and the greater the losses,
  • the length of the run from the pump to the house,
  • the required pressure at the draw-off points.

For a small pump and a short run, a narrower pipe is enough. With a higher flow or a longer distance, a wider pipe reduces resistance and the load on the pump. The specific diameter is calculated from the pump data and the run. This decision cannot be made from a table alone. We describe the run from the well to the house, the entry through the foundation and the laying depth in the article on the deep well connection.

What wall thickness of pipe for a deep well

The wall thickness follows from the pressure class and the load, not from the diameter alone. Gamrat well pipes are offered in series PN 10, PN 12.5 and PN 16. A higher class means a thicker wall and less clearance at the same nominal diameter, so with a 4-inch pump what counts is the inside diameter, not the label on the pipe.

The manufacturer notes that pipes and screens are chosen on the basis of the designer’s calculations. They are loaded by the dead weight of the column, the gravel pack and the pressure of the ground on the outside, and during operation also by the pressure difference between the inside and the outside of the pipes. There is no single correct thickness for every well. Deeper wells and ground with greater pressure require a higher class.

Permit, notification and diameter

The diameter of the pipe does not decide whether a permit is needed. Constructing an intake up to 30 m for ordinary use of water, and abstraction not exceeding 5 m³ per day on annual average for the needs of your own household or farm, are exempt from a permit and from a water-law notification (Article 33 and Article 395 of the Water Law Act, consolidated text Dz.U. 2026 poz. 1335). These are separate conditions concerning the construction of the intake and the abstraction of water. The details of the procedure are covered in the article on a deep well permit. Legal position as at 16.11.2026.

What to settle with the contractor before choosing pipes

Before ordering the borehole, prepare the data from which the contractor will choose the pipes and the pump:

  • the planned daily and peak water demand,
  • the planned pump, or its dimensions and the space for the installation,
  • the distance and the height difference to the house and the draw-off points,
  • the results of the investigation and pumping test, if the intake already exists,
  • servicing needs and planned expansion of the installation.

In the quote, specify the diameter of the hole, the type and class of the pipes, the screen parameters, the gravel pack and the scope of the pumping test. A larger size is not automatically better, and the justification should come from the design. Also check how the yield achieved is accepted and documented. Our drilling offer, with a construction chosen to suit the ground, is described on the page deep well drilling. Do you have questions about the pipes in your well or a planned borehole? Write to an ARCHE expert or call: +48 784 038 407. We will tell you what construction we would propose in the ground on your plot.

Frequently asked questions

What diameter of pipe for a deep well?

The diameter is chosen to suit the pump. We use PVC-U well pipes of 125 mm, and 110 mm with a thicker gravel pack in sandy ground. With a 4-inch pump, what counts is the inside diameter of the pipe, not the nominal size.

What pipe for a submersible pump: 32 or 40 mm?

This is the rising main, made of polyethylene, and its diameter is chosen to suit the pump flow, the length of the run and the required pressure. For a short run and a small pump a narrower pipe is enough, and with a higher flow and a longer distance a wider one reduces losses. The specific value comes from a calculation for the particular installation.

What wall thickness of pipe for a deep well?

The wall thickness depends on the pressure class, for example PN 10, PN 12.5 or PN 16, and on the depth and ground loads. A higher class gives a thicker wall and less clearance at the same nominal diameter. The choice is confirmed by the designer or the contractor.

What is the difference between a casing pipe and a well pipe?

The casing pipe stabilises the hole during drilling and, with our method, is pulled out. The well pipes, solid and screen, stay in the well permanently and form its column.

Does a wider pipe give more water?

No, the quantity of water is determined by the aquifer, the screen and the gravel pack. A wider pipe lets you fit a larger pump, but a hole that is too large for the pump worsens motor cooling.

What pipe for a concrete ring well?

This type of well is built of concrete rings, so it has no well pipe in the sense of a drilled well. The pump is chosen to suit the inside diameter of the rings.

Sources

Article author: Mateusz Skotnicki

Author

Mateusz Skotnicki

Deep well drilling expert

I am Mateusz Skotnicki, an enthusiast and specialist in deep well drilling. Welcome to a world where water is not only an essential part of life but also an endless source of inspiration.

Further reading

Next article in this topicWell enclosure: materials, appearance and how to build one step by step

Contact

Planning a deep well?

Tell us about your plot and your needs, and we will prepare a free quote for the drilling. Already have a well? We can help with servicing, the pump and water treatment.

Other articles in this topic

Free quote form

We call back within 24 hours

OFERTEO