Components and diagrams

Choosing a pump based on the well results

A pump is chosen for the flow and head at a specific duty point. The motor power alone, or the maximum values printed on the box, are not enough.

Start with the water source and the water users

Gather the pumping test result, the dynamic level, the internal diameter of the casing, the pipe route and the height of the highest outlet. Determine the flow needed when the chosen users run at the same time. For irrigation, check the required pressure and the flow of each section with the manufacturer of the devices.

If you do not have a yield test, the selection remains conditional. Do not enter a guessed inflow into the calculator just to arrive at a particular model.

What the head is made up of

Take into account the path from the dynamic level to the installation's reference point, the difference in levels to the outlet, the required pressure and the flow losses. The depth of the whole borehole is not automatically the same as the vertical distance the water has to be lifted.

Losses depend, among other things, on the diameter and length of the pipes, the flow, the fittings and the treatment devices. A margin should be justified rather than increasing the pump power arbitrarily.

Head as a sum: the path from the dynamic level, the difference in levels to the outlet, the required pressure and flow losses
The four components of head. Borehole depth is not the head.

How to compare proposals

  • Ask for the required Q/H point to be marked on the pump curve.
  • Check the compatibility of the diameter, the power supply and the controls.
  • Establish the permitted operating conditions, motor cooling and setting according to the manual.
  • Establish the protection against dry running and overload.
  • Ask about documentation, servicing and the availability of parts.

Two maximum values do not describe a common point

The maximum flow and the maximum head occur in different conditions. A quote should show the flow at the head you need, rather than putting together the two largest figures from the product data sheet.

At acceptance, keep the curve, the data of the pump chosen and the confirmed settings. For a future replacement they will be more useful than a remembered motor power.

Sources:

Checked 8 October 2026

Read and plan further

Next guidePump protection and power supply

Contact

Need help with your well?

Describe your needs or the symptoms. You can add the planner summary, test results and photos of the installation.

Other guides in this section

Free quote form

We call back within 24 hours

OFERTEO